dry block heater with blue transparent cover and 4 modules
Dry block heater, also known as dry thermostat, is a kind of laboratory temperature control equipment using metal module as the heat conduction medium, completely abandoning the traditional water bath or oil bath method to realize the constant temperature incubation of samples.
Description
Dry Block Heater
Main Features
- Intuitive operation: High-definition LCD displays temperature settings, actual temperature, timing status, and more for easy, interactive control.
- Protective structure: Blue transparent cover prevents accidental spills and reduces heat loss, improving temperature efficiency.
- Multi-zone independent control: Four heating zones (A, B, C, D) each with individual timers—supporting parallel experiments.
- Flexible module adaptation: Standard modules for 0.2mL PCR tubes, 1.5mL/2.0mL centrifuge tubes, 96-well plates, etc.; custom modules available for diverse needs.
- Automation: Automatic preheating, power failure memory/recovery, and auto-run on boot for streamlined, uninterrupted batch processes.
- Temperature calibration: Built-in deviation correction ensures data reliability via calibration with external thermometers.
- Intelligent safety: Dual (software/hardware) over-temperature protection prevents equipment/sample damage or denaturation.
Core Advantages
- High-precision temperature control: Range from room temp +5 °C to 120 °C; accuracy ±0.3 °C, highly stable.
- Maintenance-free: No liquid required—cleaner, safer than water/oil baths, with no cleaning or fluid replacement.
- Efficient: Modular, multi-area design allows simultaneous sample processing, boosting lab productivity.
- Strong compatibility: Easily swap modules for different containers; suitable for R&D and clinical testing.
- User-friendly & durable: Compact, corrosion-resistant, easy to clean, long service life, low maintenance.
Working Principle
- High-purity aluminum modules conduct heat from internal electric heater for fast, uniform temperature distribution.
- Real-time sensor feedback to a microprocessor PID controller precisely regulates heating power for stable temperature.
Application Fields
- Molecular biology: DNA/RNA extraction, PCR pre-denaturation, enzymatic digestion, inactivation, thermal repair.
- Clinical & medical research: Serum incubation, coagulation, blood sample temperature control, reagent preservation.
- Environmental & food testing: Sample pretreatment, lysis, incubation, thermal stability analysis.
- Pharmaceutical R&D: Drug component stability testing, thermo-responsive material performance evaluation.
- Education & research: Teaching experiments, small volume sample heating, constant temperature control.
Technical Parameters
| Model | DB30 |
|---|---|
| Temperature range | ambient+5°C to 110°C |
| Temperature resolution | 0.1°C |
| Temperature accuracy | ≤0.3°C, at 37°C |
| Temperature uniformity | ≤±0.2°C, at 37°C |
| Temperature rise time | ≤15 minutes, 25°C to 100°C |
| Timer | 1 minute to 99 hours 59 minutes or continuous |
| Power supply | 220Vac, 50-60Hz or 110Vac, 50-60Hz |
| Power | 500W |
| External dimensions | 370x255x180mm |
| Weight | 8kg |
| Order code | Hole diameter | Number of holes | Descriptions |
|---|---|---|---|
| mk01 | 6mm | 48 | hole depth 47mm |
| mk02 | 7mm | 48 | hole depth 47mm |
| mk03 | 10mm | 24 | hole depth 47mm |
| mk04 | 12mm | 24 | hole depth 47mm |
| mk05 | 13mm | 24 | hole depth 47mm |
| mk06 | 15mm | 16 | hole depth 47mm |
| mk07 | 16mm | 16 | hole depth 47mm |
| mk08 | 19mm | 12 | hole depth 47mm |
| mk09 | 20mm | 12 | hole depth 47mm |
| mk10 | 26mm | 8 | hole depth 47mm |
| mk11 | 28mm | 4 | hole depth 47mm |
| mk12 | 40mm | 3 | hole depth 47mm |
| mk13 | 0.2ml centrifuge tube | 48 | standard centrifuge tubes |
| mk14 | 0.5ml centrifuge tube | 48 | standard centrifuge tubes |
| mk15 | 1.5ml centrifuge tube | 24 | standard centrifuge tubes |
| mk16 | 2.0ml centrifuge tube | 24 | standard centrifuge tubes |
| mk17 | 0.2ml PCR tube | 96 | Cannot be used for DB20-1 model |
| mk18 | 0.2ml zymography plate | 96 | Cannot be used for DB20-1 model |
| Note | modules mk17 and mk18 are twice as large as other standard modules | ||






English
Français
Tiếng Việt
Italiano
Nederlands
Türkçe
Svenska
Polski
Română
Latviešu
한국어
Русский
Español
Deutsch
Українська
Português
العربية
Indonesian
Čeština
Suomi
Eesti
Български
Dansk
Lietuvių
Bokmål
Slovenčina
Slovenščina
Ελληνικά
Magyar
עברית 