fixed volume pipette with precision calibration function

Fixed volume pipettes are manual pipetting tools with a specific preset volume that cannot be adjusted. Compared to adjustable pipettes, they have a simpler structure and a more stable set volume.

Description

Fixed Volume Pipette

Main Features

  1. Air displacement principle: Delivers precise, repeatable volume via robust piston mechanism.
  2. Centered, enlarged pipetting button: Ergonomic and easy for thumb operation—smooth, stable piston movement.
  3. Ergonomic finger rest: Fits all hand sizes and reduces fatigue during extended use.
  4. Clear capacity markings: Instantly visible—prevents mix-ups of different volume ranges.
  5. Fully autoclavable: Sterilize entire pipette at 121°C for 20 min—no disassembly needed.
  6. Slender rod design: Easily accesses narrow containers like centrifuge tubes and test tubes.
  7. Universal cone: Compatible with tips from major brands—eliminates repeated sourcing headaches.
  8. Quick calibration: Simple tool-based calibration keeps accuracy long-term.

Core Advantages

  1. Fixed volume, minimal error: Factory set and calibrated—error control better than ±1%.
  2. Simple operation: No adjustments required—ideal for repetitive same-volume tasks.
  3. Durable build: High-quality plastics and ceramic piston—corrosion-resistant, long lifespan.
  4. Low training cost: Easy for students/technicians to learn and use in teaching, QC environments.

Working Principle

Operates via air displacement. Button press moves piston down to expel air; release generates negative pressure to aspirate liquid; press again to dispense. Volume is preset at the factory and not adjustable—ensures stable accuracy over time.

Typical Applications

  1. Life science: PCR, DNA extraction, ELISA, enzyme analysis—standard, repeated sample removal.
  2. Biochemical/QC testing: Batch testing, SOPs for food, pharma, environmental labs.
  3. Education/training: Simple for students and teaching labs—reduces operational errors.
  4. Hospital/clinical diagnostics: Fast, accurate, repeated sample addition for analysis workflows.
Technical Parameters
fixed volume pipette with precision calibration function
Model Volume range Accuracy Coefficient of variation
PF05H 5 uL ±2.0% ±0.1 uL ±0.80% ±0.04 uL
PF10H 10 uL ±1.0% ±0.1 uL ±0.50% ±0.05 uL
PF20H 20 uL ±1.0% ±0.2 uL ±0.30% ±0.06 uL
PF25H 25 uL ±1.0% ±0.25 uL ±0.30% ±0.075 uL
PF50H 50 uL ±1.0% ±0.5 uL ±0.30% ±0.15 uL
PF100H 100 uL ±1.0% ±1.0 uL ±0.25% ±0.25 uL
PF200H 200 uL ±0.8% ±1.6 uL ±0.20% ±0.4 uL
PF250H 250 uL ±0.8% ±2.0 uL ±0.20% ±0.5 uL
PF500H 500 uL ±0.8% ±4.0 uL ±0.20% ±1.0 uL
PF1000H 1000 uL ±0.8% ±8.0 uL ±0.20% ±2.0 uL